2600 Family Instruction Manual
25
Chapter 4 : Serial Communication Server
Response (Status)
4.4.12 BreakChar
Function Specifies the Break character.
Opcode 0x0B
Command (BreakChar)
Response (Status)
Notes The default break character is a NULL (0x00).
The break character may be changed at any time,
regardless of whether the target comport is open.
4.5 Specifications
See Section 2.4 for com port specifications.
Parameter Function
Status Com port status. The REJ flag will be
set if the port is closed.
Parameter Function
BreakChar Character that is to be stored in the
receive buffer upon detection of an
incoming break condition.
Parameter Function
Status Com port status.