INSTRUCTION MANUAL Sensoray Model 2411 Still Image Capturing Server Revision 1.2 Aug 26, 2005
Appendix-II: Instruction to Enable Hard Drive (for Sensoray 24xx only) 1. Install Sensoray’s model 300TA, connect IDE flat cable and power cable
Appendix-III: Instruction to GPIO and Push Button Driver (for Sensoray 2411/311/611 only) 1) with any ftp utility like FileZilla, load the distribu
I. Introduction: The Sensoray model 2411 stack consists of a Sensoray Model 301 CPU board, one/two Sensoray Model 311 frame grabber board(s), a Sen
The v4l (Video4Linux) bttv is used for frame capturing driver in the 2411. All related modules are pre-built and distributed with 2411 embedded Linux
12. vi is a small editor, loosely based on old WordStar. If the display is incorrect, type ‘ctrl – R’. If vi refuses to start, your telnet client is e
IV. Accessing 2411 via FTP: The 2411 can be accessed via FTP (either command line based FTP or Windows based FTP). This is an easy way for the 2411
1. Connect a video source to J2 (BNC connector) on Model 311. 2. Make sure 311 jumper settings are one of the following combinations for configurat
the new executable app code from host to the 2411 target system via FTP. Then run the app for test. Refer to Appendix-I for the instructions on operat
Appendix-I: Instruction to Using PC-Card type of Storage Media (CompactFlash, MicroDrive, and HardDrive) (for Sensoray 24xx only) 1) check the PC
5) run "mount" and make sure that "/dev/hda1 on /mnt/cflash type msdos (rw)" is in the displayed message. If you see it, it shows